 TUV Telecom Services, Inc.
1775 Old Highway 8 NW Suite 107 St. Paul, MN USA 55112 Tel. +1 (651) 639-0775 Fax. +1 (651) 639-0873
TEST REPORT NO. CTR13/081701/99
Date: August 26, 1999 Total Number of Pages: 34
Equipment: PM4351 Comet Client: PMC-Sierra Address: 105-8555 Baxter Place Burnaby, B.C. V5A 4V7 Canada
European Harmonised Standard: CTR 12 European Harmonised Standard: CTR 13
Authorised Signature:
August 26, 1999
Date
David A. Freemore
Name
Lead Engineer
Title Signature
The contents of this test report must not be reproduced unless in full without the written permission of TUV Telecom Services, Inc. The copyright in respect of this test report is owned by TUV Telecom Services, Inc. The results of all measurements stated in this test report only relate to the tested product.
Registration No. P004F001
Page 1 of 34
Test Report No.: CTR13/081701/99
TUV Telecom Services, Inc. 1775 Old Highway 8 NW Suite 107, St. Paul, MN 55112 Tel. +1 (651) 639-0775 Fax. +1 (651) 639-0873
August 26, 1999 Page 2 of 34
Table of contents
1 IDENTIFICATION SUMMARY
1.1 Test Laboratory 1.2 Limits and Reservations 1.3 Client Information 1.4 Product 1.4.1 IUT Identification 1.4.2 System under Test (SUT) 1.4.3 Type of Product 1.5 Nature of Conformance Testing
3
3 3 3 3 4 4 4 5
2 TEST CONDITIONS
2.1 Environmental Conditions 2.2 Power Supply Limitations
5
5 5
3 SYSTEM REPORT SUMMARY
3.1 Test Report Summary
6
6
4 OBSERVATIONS 5 SUMMARY OF COMPLIANCE
5.1 Summary of Overvoltage Protection
7 7
7
6 PROTOCOL CONFORMANCE TEST REPORT
6.1 Protocol Conformance Test Report Layer 1 6.1.1 Dates 6.1.2 Operator 6.1.3 Test System 6.1.4 Test Environment 6.5 Test Results
8
8 8 8 8 8 9
7 PHOTOGRAPHS 8 TEST DATA
11 13
Test Report No.: CTR13/081701/99
TUV Telecom Services, Inc. 1775 Old Highway 8 NW Suite 107, St. Paul, MN 55112 Tel. +1 (651) 639-0775 Fax. +1 (651) 639-0873
August 26, 1999 Page 3 of 34
1
1.1
IDENTIFICATION SUMMARY
Test Laboratory
TUV Telecom Services, Inc. 1775 Old Highway 8, Suite 107 St. Paul, MN USA 55112 Tel. +1 (651) 639-0775 Fax. +1 (651) 639-0873 UKAS accredited testing laboratory, no. 1845
1.2
Limits and Reservations
This test report satisfies European Standard EN 45001 (1989), ISO Guide 25, NIST Handbook 150 and NAMAS accreditation standard M10. The test results in this test report apply only to the particular System under Test (SUT) and component Implementations under Test (IUTs) declared in this test report.
1.3
Name Street City Country Phone Fax
Client Information
: PMC-Sierra : 105-8555 Baxter Place : Burnaby, B.C. V5A 4V7 : Canada : +1 (604) 415-6000 : +1 (604) 415-6206 : Fayaz Khaki : +1 (604) 415-6000 : +1 (604) 415-6206
Contact Person Phone Fax
1.4
Product
: PMC-Sierra : 105-8555 Baxter Place : Burnaby, B.C. V5A 4V7 : Canada : +1 (604) 415-6000 : +1 (604) 415-6206
Supplier's name Street City Country Phone Fax
Test Report No.: CTR13/081701/99
TUV Telecom Services, Inc. 1775 Old Highway 8 NW Suite 107, St. Paul, MN 55112 Tel. +1 (651) 639-0775 Fax. +1 (651) 639-0873
August 26, 1999 Page 4 of 34
1.4.1 IUT Identification
Name Version/Model Serial No. Interface board Chip set Transformer Connector types Interfaces Software and Version PM4351 Comet Comet Reference Design Board Rev. 2 83110-2-0001 -PM4351 Comet Rev. F Midcom 50436 Bantam 2 at E1 --
1.4.2 System under Test (SUT)
(If applicable) SUT Configuration for testing (PC, Bus System, Clock etc.) Operating System Version No. Miscellaneous Motherboard used for microprocessor interface
----
1.4.3 Type of Product
Monolithic device which integrates software selectable full featured T1 and E1 framers and T1 and E1 shorthand and longhand line interfaces
Test Report No.: CTR13/081701/99
TUV Telecom Services, Inc. 1775 Old Highway 8 NW Suite 107, St. Paul, MN 55112 Tel. +1 (651) 639-0775 Fax. +1 (651) 639-0873
August 26, 1999 Page 5 of 34
1.5
Nature of Conformance Testing
The purpose of Conformance Testing is to increase the probability that different implementations can interwork. However, the complexity of OSI protocols makes exhaustive testing impractical on both technical and economic grounds. Furthermore, there is no guarantee that an IUT which has passed all the relevant tests conforms to a specification. Neither is there any guarantee that such an IUT will interwork with other real open systems. Rather, the passing of the tests gives confidence that the IUT has the stated capabilities and that its behaviour conforms consistently in representative instances of communication.
2
2.1
Test Conditions
Environmental Conditions
: In the range of 19C to 25C : In the range of 10% to 75% ( ) Yes ( ) Yes ( )No ( )No
Temperature Relative humidity
2.2
Power Supply Limitations
All tests were carried out within +/- 5% of the normal operating voltage of 5.0 VDC.
Test Report No.: CTR13/081701/99
TUV Telecom Services, Inc. 1775 Old Highway 8 NW Suite 107, St. Paul, MN 55112 Tel. +1 (651) 639-0775 Fax. +1 (651) 639-0873
August 26, 1999 Page 6 of 34
3
3.1
System Report Summary
Test Report Summary
TBR 12 (12.93) TBR 12 A1 (01.96) TBR 13 (01.96)
Protocol Standard:
Protocol Conformance Test Report: Abstract Test Suite (ATS) Standard:
See Section 6 TBR 12 (12.93) TBR 13 (01.96)
Abstract Test Method: Remote Single Layer Embedded (RSE) Real Test system: Executable Test Suite (ETS) Identification: Name : CTS Layer 1 Conformance Tests Version : A.09.10 Test system Identification: ISDN-S2M-Test System IPATS: Manufacturer : Hewlett Packard / Admit Design Systems
Conformance Status: Static Conformance Errors : Dynamic Conformance Errors : Test cases run: 5 Passed Failed :5 :0 No No
Test Report No.: CTR13/081701/99
TUV Telecom Services, Inc. 1775 Old Highway 8 NW Suite 107, St. Paul, MN 55112 Tel. +1 (651) 639-0775 Fax. +1 (651) 639-0873
August 26, 1999 Page 7 of 34
4
Observations
Date: August 17, 1999 No observations have been made during the conformance assessment test.
5
Summary of Compliance
Date: August 17, 1999 The test results in this test report apply only to the particular System under Test (SUT) and component Implementations under Test (IUTs) declared in this test report. The SUT/IUT has not been shown by the conformance assessment to be non-conforming to the specified protocol standard. The test campaign did not reveal errors in the SUT/IUT.
5.1
Summary of Overvoltage Protection
Date: August 17, 1999 The IUT complies with TBR 12 paragraph 5.4, subclause 5.4.1, 5.4.2 and 5.4.3. The IUT complies with TBR 13 paragraph 4.4, subclause 4.4.1, 4.4.2 and 4.4.3. For full test results see test report 046/081701/99
Test Report No.: CTR13/081701/99
TUV Telecom Services, Inc. 1775 Old Highway 8 NW Suite 107, St. Paul, MN 55112 Tel. +1 (651) 639-0775 Fax. +1 (651) 639-0873
August 26, 1999 Page 8 of 34
6
6.1
Protocol Conformance Test Report
Protocol Conformance Test Report Layer 1
6.1.1 Dates
Receipt of SUT/IUT: Date of Test: August 16, 1999 August 17, 1999
6.1.2 Operator
Dan Thayer
(Signature)
6.1.3 Test System
Name Version : CTS Layer 1 Conformance Tests : A.09.10
Test system Identification: ISDN-S2M-Test System IPATS: Manufacturer : Hewlett Packard / Admit Design Systems
6.1.4 Test Environment
Temperature : In the range of 19C to 25C Relative humidity : In the range of 25% to 75% ( ) Yes ( ) Yes ( )No ( )No
All tests are carried out within +/- 5% of the normal operating voltage of 5.0 VDC.
Protocol Conformance Test Report
Test Report No.: CTR13/081701/99
TUV Telecom Services, Inc. 1775 Old Highway 8 NW Suite 107, St. Paul, MN 55112 Tel. +1 (651) 639-0775 Fax. +1 (651) 639-0873
August 26, 1999 Page 9 of 34
6.5
Test Results
TBR 12 / 13 5.2.1.1 / 4.2.1.1 5.2.1.2 / 4.2.1.2 Result HDB3 code, no errors Puls shape Peak voltage of space Puls ampl. ratio Puls width ratio see graphs below < 0.1V 1.014 1.000 Verdict pass pass pass pass pass Comment
Test Case A.2.1 A.2.2
Protocol Conformance Test Report
Test Report No.: CTR13/081701/99
TUV Telecom Services, Inc. 1775 Old Highway 8 NW Suite 107, St. Paul, MN 55112 Tel. +1 (651) 639-0775 Fax. +1 (651) 639-0873
August 26, 1999 Page 10 of 34
Test Case A.2.3 A.2.4
TBR 12 / 13 5.2.1.3 / 4.2.1.3 5.2.1.4 / 4.2.1.4
Result +30.55 ppm 20 Hz 0 ppm +50 ppm -50 ppm 2400 Hz 0 ppm +50 ppm -50 ppm 18 KHz 0 ppm +50 ppm -50 ppm 100 KHz 0 ppm +50 ppm -50 ppm
0.056 UI 0.058 UI 0.059 UI 0.014 UI 0.015 UI 0.019 UI 0.014 UI 0.015 UI 0.018 UI 0.014 UI 0.015 UI 0.018 UI
Verdict pass pass
Comment
pass
pass
pass
Test Case A.2.5
TBR 13 4.2.1.5
Result Frame Alignment / CRC-4 / A-bit
Verdict pass
Comment
Protocol Conformance Test Report
Test Report No.: CTR13/081701/99
TUV Telecom Services, Inc. 1775 Old Highway 8 NW Suite 107, St. Paul, MN 55112 Tel. +1 (651) 639-0775 Fax. +1 (651) 639-0873
August 26, 1999 Page 11 of 34
7
Photographs
Photographs
Test Report No.: CTR13/081701/99
TUV Telecom Services, Inc. 1775 Old Highway 8 NW Suite 107, St. Paul, MN 55112 Tel. +1 (651) 639-0775 Fax. +1 (651) 639-0873
August 26, 1999 Page 12 of 34
Photographs
Test Report No.: CTR13/081701/99
TUV Telecom Services, Inc. 1775 Old Highway 8 NW Suite 107, St. Paul, MN 55112 Tel. +1 (651) 639-0775 Fax. +1 (651) 639-0873
August 26, 1999 Page 13 of 34
8
Test Data
Test Data
Test Report No.: CTR13/081701/99
TUV Telecom Services, Inc. 1775 Old Highway 8 NW Suite 107, St. Paul, MN 55112 Tel. +1 (651) 639-0775 Fax. +1 (651) 639-0873
August 26, 1999 Page 14 of 34
Test Data
Test Report No.: CTR13/081701/99
TUV Telecom Services, Inc. 1775 Old Highway 8 NW Suite 107, St. Paul, MN 55112 Tel. +1 (651) 639-0775 Fax. +1 (651) 639-0873
August 26, 1999 Page 15 of 34
Test Data
Test Report No.: CTR13/081701/99
TUV Telecom Services, Inc. 1775 Old Highway 8 NW Suite 107, St. Paul, MN 55112 Tel. +1 (651) 639-0775 Fax. +1 (651) 639-0873
August 26, 1999 Page 16 of 34
Test Data
Test Report No.: CTR13/081701/99
TUV Telecom Services, Inc. 1775 Old Highway 8 NW Suite 107, St. Paul, MN 55112 Tel. +1 (651) 639-0775 Fax. +1 (651) 639-0873
August 26, 1999 Page 17 of 34
Test Data
Test Report No.: CTR13/081701/99
TUV Telecom Services, Inc. 1775 Old Highway 8 NW Suite 107, St. Paul, MN 55112 Tel. +1 (651) 639-0775 Fax. +1 (651) 639-0873
August 26, 1999 Page 18 of 34
Test Data
Test Report No.: CTR13/081701/99
TUV Telecom Services, Inc. 1775 Old Highway 8 NW Suite 107, St. Paul, MN 55112 Tel. +1 (651) 639-0775 Fax. +1 (651) 639-0873
August 26, 1999 Page 19 of 34
Test Data
Test Report No.: CTR13/081701/99
TUV Telecom Services, Inc. 1775 Old Highway 8 NW Suite 107, St. Paul, MN 55112 Tel. +1 (651) 639-0775 Fax. +1 (651) 639-0873
August 26, 1999 Page 20 of 34
Test Data
Test Report No.: CTR13/081701/99
TUV Telecom Services, Inc. 1775 Old Highway 8 NW Suite 107, St. Paul, MN 55112 Tel. +1 (651) 639-0775 Fax. +1 (651) 639-0873
August 26, 1999 Page 21 of 34
Test Data
Test Report No.: CTR13/081701/99
TUV Telecom Services, Inc. 1775 Old Highway 8 NW Suite 107, St. Paul, MN 55112 Tel. +1 (651) 639-0775 Fax. +1 (651) 639-0873
August 26, 1999 Page 22 of 34
Test Data
Test Report No.: CTR13/081701/99
TUV Telecom Services, Inc. 1775 Old Highway 8 NW Suite 107, St. Paul, MN 55112 Tel. +1 (651) 639-0775 Fax. +1 (651) 639-0873
August 26, 1999 Page 23 of 34
Test Data
Test Report No.: CTR13/081701/99
TUV Telecom Services, Inc. 1775 Old Highway 8 NW Suite 107, St. Paul, MN 55112 Tel. +1 (651) 639-0775 Fax. +1 (651) 639-0873
August 26, 1999 Page 24 of 34
Test Data
Test Report No.: CTR13/081701/99
TUV Telecom Services, Inc. 1775 Old Highway 8 NW Suite 107, St. Paul, MN 55112 Tel. +1 (651) 639-0775 Fax. +1 (651) 639-0873
August 26, 1999 Page 25 of 34
Test Data
Test Report No.: CTR13/081701/99
TUV Telecom Services, Inc. 1775 Old Highway 8 NW Suite 107, St. Paul, MN 55112 Tel. +1 (651) 639-0775 Fax. +1 (651) 639-0873
August 26, 1999 Page 26 of 34
Test Data
Test Report No.: CTR13/081701/99
TUV Telecom Services, Inc. 1775 Old Highway 8 NW Suite 107, St. Paul, MN 55112 Tel. +1 (651) 639-0775 Fax. +1 (651) 639-0873
August 26, 1999 Page 27 of 34
Test Data
Test Report No.: CTR13/081701/99
TUV Telecom Services, Inc. 1775 Old Highway 8 NW Suite 107, St. Paul, MN 55112 Tel. +1 (651) 639-0775 Fax. +1 (651) 639-0873
August 26, 1999 Page 28 of 34
Test Data
Test Report No.: CTR13/081701/99
TUV Telecom Services, Inc. 1775 Old Highway 8 NW Suite 107, St. Paul, MN 55112 Tel. +1 (651) 639-0775 Fax. +1 (651) 639-0873
August 26, 1999 Page 29 of 34
Test Data
Test Report No.: CTR13/081701/99
TUV Telecom Services, Inc. 1775 Old Highway 8 NW Suite 107, St. Paul, MN 55112 Tel. +1 (651) 639-0775 Fax. +1 (651) 639-0873
August 26, 1999 Page 30 of 34
Test Data
Test Report No.: CTR13/081701/99
TUV Telecom Services, Inc. 1775 Old Highway 8 NW Suite 107, St. Paul, MN 55112 Tel. +1 (651) 639-0775 Fax. +1 (651) 639-0873
August 26, 1999 Page 31 of 34
Test Data
Test Report No.: CTR13/081701/99
TUV Telecom Services, Inc. 1775 Old Highway 8 NW Suite 107, St. Paul, MN 55112 Tel. +1 (651) 639-0775 Fax. +1 (651) 639-0873
August 26, 1999 Page 32 of 34
Test Data
Test Report No.: CTR13/081701/99
TUV Telecom Services, Inc. 1775 Old Highway 8 NW Suite 107, St. Paul, MN 55112 Tel. +1 (651) 639-0775 Fax. +1 (651) 639-0873
August 26, 1999 Page 33 of 34
Test Data
Test Report No.: CTR13/081701/99
TUV Telecom Services, Inc. 1775 Old Highway 8 NW Suite 107, St. Paul, MN 55112 Tel. +1 (651) 639-0775 Fax. +1 (651) 639-0873
August 26, 1999 Page 34 of 34
Test Data


▲Up To Search▲   

 
Price & Availability of 1991291

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X